>Hi
>When running TAS under TSO and choosing PAR, I get the following:
>CPU  Serial Numb   RelSpeed
> 00  0008B0BF2094      1000
> 01  0008B0BF2094      1000
> 02  0008B0BF2094      1000

>What does this all mean?  The Serial Numb is the same across all
>three.

The serial number looks like the output from STIDP (Store CPU ID)
where the format is:
version code - 1 byte (00)
Logical Partition ID - 1 byte
CEC serial number - 2 bytes
Machine type - 2 bytes

Actually there are another 2 bytes at the end where the
first bit is the format type. This is format 1 output.

George Kozakos