<continuing top-posting>
You can setup a default value for unit in your sms configuration.
Regards,
John
> I have worked on numerous systems that never had SYSALLDA setup in HCD or

> ALLOCxx and never had a problem running TSO BATCH. The default for
generic
> for DASD is 3390 that has no ESOTERIC assigned to it.
> I tired a Randy's job on Zos14 and a Zos17 and it ran fine without any
> SYSALLDA in esotrics or a ALLOCxx and without adding the unit to the JCL.

>
>
>
>
> From:
> Steven Conway <[EMAIL PROTECTED]>
> To:
> IBM-MAIN@BAMA.UA.EDU
> Date:
> 02/22/2008 10:17 AM
> Subject:
> Re: ZOS Upgrade Issue
>
>
>
> Randy, without ALLOCxx in your PARMLIB concatenation, the default device
> will be SYSALLDA.  If that's not defined in your gen, it would explain
the
>
> failure.  A browse thru HCD would be interesting.
>
>
> Cheers,,,Steve
>
> Steve Conway
> Lead Systems Programmer
> Information Systems & Services Division
> Computer & Network Operations
> Phone:   (703) 450-3156
> Fax:        (703) 450-3197
>
> ----------------------------------------------------------------------