If I run a job with the following two IDCAMS commands, the second
command, DEF ALIAS, fails with

IDC3013I DUPLICATE DATA SET NAME


IMPORT CONNECT -
   OBJECTS (( -
    TSSTV.ICF.VBV0001 -
      VOL(BV1075) DEVT(3390) -
      )) CAT(CATALOG.ICF.VI24CAT.MCAT)

 DEF ALIAS(NAME(TSSTV) RELATE(CATALOG.ICF.VTSTH01)) -
     CAT(CATALOG.ICF.VI24CAT.MCAT)

However, if I run the DEF ALIAS followed by the IMPORT CONNECT, all is
wonderful. Does this seem inconsistent to anybody else? I do have the
multilevel alias active, with a level of 2.

--