>All of our DASD subsystems are EMCs, I want to know if it's possible to 
>implement PAV on DASD made by EMC? Can it be defined as Control UNIT=2105?
Currently, it is defined as CONTROL UNIT=3990 and IODEVICE UNIT=3390 in the 
IOCDS.

EMC came out with PAV support, years ago.
So, as long as you are at z/OS 1.3 (or higher) the answer is yes.
(Former EMC customer).

-
Too busy driving to stop for gas!

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to