After start Netview new sesion:

AUTO1 CNM02 17:43:10 - DSI205I 000 TIMER ELEMENTS PURGED OP = 'AUTO1' AUTO1 CNM02 17:43:10 - DSI034I COMMAND SCHEDULED BY AT/EVERY/AFTER COMMAND - 'IDLEOFF 480 469'
AUTO1    CNM02    17:43:10 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 
'ID=IDLEOFF'
AUTO1 CNM02 17:43:10 C DWO971I IDLEOFF : OPER1 ADDED TO EXCEPTOP LIST AUTO1 CNM02 17:43:10 C DWO971I IDLEOFF : NETOP1 ADDED TO EXCEPTOP LIST AUTO1 CNM02 17:43:10 C DWO976I IDLEOFF : EXCEPTOP: AUTO1 CNM02 17:43:10 ! OPER1 AUTO1 CNM02 17:43:10 ! NETOP1 AUTO1 CNM02 17:43:10 C DWO976I IDLEOFF : EXCEPTLU: NONE AUTO1 CNM02 17:43:10 C DWO976I IDLEOFF : EXCEPTAUTO: NONE AUTO1 CNM02 17:43:10 C DWO976I IDLEOFF : EXCEPTNNT: NONE AUTO1 CNM02 17:43:10 C DWO976I IDLEOFF : EXCEPTRMTCMD: NONE AUTO1 CNM02 17:43:10 - CNM493I DSITBL01 : #0000151 : CNME2001
AUTO1    CNM02    17:43:10 C DWO975I IDLEOFF : NO ACTIVE TASKS ARE EXEMPT FROM 
IDLE TIME LIMITS
multiple 5 times from:

AUTO1 CNM02 17:43:10 ! OPER1 .....
.....

nezt multiple 10 times something like this:

AUTO1    CNM02    17:43:11 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 
'ID=SYS00001'
                                -  "   -                                      
SYS00002'
                                -  "   -                                      
.........
- " - do SYS00010'
at 7:00 we have:

BODZIO   CNM02    07:00:00 - DSI034I COMMAND SCHEDULED BY AT/EVERY/AFTER 
COMMAND - 'NLDM COLLECT RTM * LOG'
BODZIO   CNM02    07:00:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 
'ID=NLDMC'
BODZIO CNM02 07:00:00 - DSI204I TIMER REQUEST ID NOT UNIQUE ID = 'NLDMC' BODZIO CNM02 07:00:00 - DSI202I TIMER REQUEST FAILED TO BE SCHEDULED FOR EXECUTION 'ID=NLDMC'
last 2 rows we see 4 times..
and next :

BODZIO CNM02 P 07:00:00 E ERB100I AA : ACTIVE BODZIO CNM02 P 07:00:00 E ERB200I AA : ALREADY ACTIVE BODZIO CNM02 P 07:00:00 E ERB200I AA : ALREADY ACTIVE BODZIO CNM02 P 07:00:00 E ERB200I AA : ALREADY ACTIVE BODZIO CNM02 P 07:00:00 E ERB200I AA : ALREADY ACTIVE
where I search now ?
how can I imit which operator executed CNME2001 if it's a problem ?

Thanks for your help....

John S. Giltner, Jr. napisa?(a):
What is the userid that is associated with the messages?

These are not duplicate messages, the commands are getting issued multiple times, 5 times to be exact. This is evident because of the messages that the TIMER ID is not unique and the member AA is already active.

It is almost as if multiple (5) automated operators are executing CNME2001. Do you limit which operator executed CNME2001?




Rafa? Hanzel ZETO wrote:
In CNME2001 we use
CHRON AT=(07:00:00) +
COMMAND='EVERY &P1,PPT,ID=NLDMC,NLDM COLLECT RTM * LOG' ROUTE=PPT
and additionally we run

CHRON AT=(07:00:00) +
COMMAND='MVS F RMF,START AA,MEMBER(11)' ROUTE=PPT

In Netlog at 7.00 we see :

DSI034I COMMAND SCHEDULED BY AT/EVERY/AFTER COMMAND - 'NLDM COLLECT RTM * LOG'
DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=NLDMC'
DSI204I TIMER REQUEST ID NOT UNIQUE ID = 'NLDMC'
DSI202I TIMER REQUEST FAILED TO BE SCHEDULED FOR EXECUTION 'ID=NLDMC'
DSI204I TIMER REQUEST ID NOT UNIQUE ID = 'NLDMC'
DSI202I TIMER REQUEST FAILED TO BE SCHEDULED FOR EXECUTION 'ID=NLDMC'
DSI204I TIMER REQUEST ID NOT UNIQUE ID = 'NLDMC'
DSI202I TIMER REQUEST FAILED TO BE SCHEDULED FOR EXECUTION 'ID=NLDMC'
DSI204I TIMER REQUEST ID NOT UNIQUE ID = 'NLDMC'
DSI202I TIMER REQUEST FAILED TO BE SCHEDULED FOR EXECUTION 'ID=NLDMC'
ERB100I AA : ACTIVE
ERB200I AA : ALREADY ACTIVE

ERB200I AA : ALREADY ACTIVE

ERB200I AA : ALREADY ACTIVE

ERB200I AA : ALREADY ACTIVE


John S. Giltner, Jr. napisa?(a):
Do you see anything in NetView's log?

I am not sure if you are actually seeing the same message duplicated or if something is happening multiple times.

Do OPER1 and NETOP1 have an console assigned to them?


Rafa? Hanzel ZETO wrote:
We running Netview without SUB=MSTR.
In SYSLOG we see :

0290 IEA630I OPERATOR CNM0T02 NOW ACTIVE, SYSTEM=CPAC , LU=CNM02PPT
0290 F RMF,START AA,MEMBER(11)
0290 F RMF,START AA,MEMBER(11)
0290 F RMF,START AA,MEMBER(11)
0290 F RMF,START AA,MEMBER(11)
0290 F RMF,START AA,MEMBER(11)


In CNME2001 we have :

CHRON AT=(07:00:00) +
COMMAND='MVS F RMF,START AA,MEMBER(11)' ROUTE=PPT


maybe this will be helpful to recognize this problem.After we start Netview we receive something like this :

18:52:00 - DSI205I 000 TIMER ELEMENTS PURGED OP = 'AUTO1'
18:52:00 - DSI034I COMMAND SCHEDULED BY AT/EVERY/AFTER COMMAND - 'IDLEOFF
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=IDLEOFF'
18:52:00 C DWO971I IDLEOFF : OPER1 ADDED TO EXCEPTOP LIST
18:52:00 C DWO971I IDLEOFF : NETOP1 ADDED TO EXCEPTOP LIST
18:52:00 C DWO976I IDLEOFF : EXCEPTOP:
18:52:00 ! OPER1
18:52:00 ! NETOP1
18:52:00 C DWO976I IDLEOFF : EXCEPTLU: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTAUTO: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTNNT: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTRMTCMD: NONE
18:52:00 - CNM493I DSITBL01 : #0000151 : CNME2001
18:52:00 C DWO975I IDLEOFF : NO ACTIVE TASKS ARE EXEMPT FROM IDLE TIME LIMITS
18:52:00 C DWO976I IDLEOFF : EXCEPTOP:
18:52:00 ! OPER1
18:52:00 ! NETOP1
18:52:00 C DWO976I IDLEOFF : EXCEPTLU: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTAUTO: ALL
18:52:00 C DWO976I IDLEOFF : EXCEPTNNT: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTRMTCMD: NONE
18:52:00 - CNM493I DSITBL01 : #0000151 : CNME2001
18:52:00 C DWO975I IDLEOFF : NO ACTIVE TASKS ARE EXEMPT FROM IDLE TIME LIMITS
18:52:00 C DWO976I IDLEOFF : EXCEPTOP:
18:52:00 ! OPER1
18:52:00 ! NETOP1
18:52:00 C DWO976I IDLEOFF : EXCEPTLU: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTAUTO: ALL
18:52:00 C DWO976I IDLEOFF : EXCEPTNNT: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTRMTCMD: NONE
18:52:00 - CNM493I DSITBL01 : #0000151 : CNME2001
18:52:00 C DWO975I IDLEOFF : NO ACTIVE TASKS ARE EXEMPT FROM IDLE TIME LIMITS
18:52:00 C DWO976I IDLEOFF : EXCEPTOP:
18:52:00 ! OPER1
18:52:00 ! NETOP1
18:52:00 C DWO976I IDLEOFF : EXCEPTLU: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTAUTO: ALL
18:52:00 C DWO976I IDLEOFF : EXCEPTNNT: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTRMTCMD: NONE
18:52:00 - CNM493I DSITBL01 : #0000151 : CNME2001
18:52:00 C DWO975I IDLEOFF : NO ACTIVE TASKS ARE EXEMPT FROM IDLE TIME LIMITS
18:52:00 C DWO976I IDLEOFF : EXCEPTOP:
18:52:00 ! OPER1
18:52:00 ! NETOP1
18:52:00 C DWO976I IDLEOFF : EXCEPTLU: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTAUTO: ALL
18:52:00 C DWO976I IDLEOFF : EXCEPTNNT: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTRMTCMD: NONE
18:52:00 - CNM493I DSITBL01 : #0000151 : CNME2001
18:52:00 C DWO975I IDLEOFF : NO ACTIVE TASKS ARE EXEMPT FROM IDLE TIME LIMITS
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00001'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00002'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00003'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00004'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00005'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00006'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00007'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00008'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00009'
18:52:00 - DSI201I TIMER REQUEST SCHEDULED FOR EXECUTION 'ID=SYS00010'

As we see this piece of information duplicated 5 times:
18:52:00 C DWO976I IDLEOFF : EXCEPTOP:
18:52:00 ! OPER1
18:52:00 ! NETOP1
18:52:00 C DWO976I IDLEOFF : EXCEPTLU: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTAUTO: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTNNT: NONE
18:52:00 C DWO976I IDLEOFF : EXCEPTRMTCMD: NONE
18:52:00 - CNM493I DSITBL01 : #0000151 : CNME2001
18:52:00 C DWO975I IDLEOFF : NO ACTIVE TASKS ARE EXEMPT FROM IDLE TIME LIMITS




Bruce Hewson napisa?(a):
Hello Rafal,

Are you running your Netview task as SUB=MSTR?

Please provide sample of duplicated messages.

Thanks
Bruce Hewson


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html



--
Best regards,

Rafa? Hanzel
Systems Programmer, R&D of Computer System Department
Z.E.T.O Katowice Sp. z o.o.
ul. Owocowa 1
40-158 Katowice, Poland
Phone: +48 32 3589 246
e-mail: [EMAIL PROTECTED]

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to