On Wed, 5 Mar 2008 12:00:20 -0800, Edward Jaffe
<[EMAIL PROTECTED]> wrote:

>Mark Zelden wrote:
>> What do you have specified or defaulted for MNTS?  Did that change in
>> recent years?  I see the default is still documented as 3:00
>>
>
>IOS086I 09.46.38 MIH AND IOT TIMES 889
> MOUNTMSG =  YES,        HALT=00:05, MNTS=03:00, UREC=03:00,
> DASD=00:15, TAPE=03:00, GRAF=03:00, CTC =03:00, COMM=03:00,
> CHAR=03:00, IOTDASD=00:00,
>

Looks like it's time to open a PMR (I just did a quick IBMLINK search
and came up empty).   Please post your results.  I am very interested
also because we have not rolled out 1.9 yet but will be doing so soon.
I have MNTS set to 12 minutes (because it could take that long to recall
a virtual tape from the back end) and we have automation in place to
alert operations of possible virtual tape issues if the mount pending message
is displayed.