Hi folks,

Want to confirm that, at z/OS 1.7, RMF Monitor III is not able to identify 
delays due to PDSE latch contention.

We had a lot of batch jobs, all hung, with RMF showing them all 100% 
Unknown delay.

Before I go chasing IBM I just wanted to check that this is still the same at 
later levels of RMF.

I am sure that RMF should be able to detect job delay due to:

1. PDSE latch contention.
2. OMVS delays
3. maybe even TCPIP delays.

and it would be real nice if it could make a guess at delays due to 3rd party 
software ( wishful thinking?? )

Regards
Bruce Hewson

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to