HMC--defined to MVS as SYSCONS--works great on several levels. You don't
have to worry about...

-- Altered console configurations

-- Flaky tubes/PCs/controllers

-- Updating SAD procedures

We don't take many standalone dumps, but three changes in the past several
years have greatly improved reliability:

1, Use only SYSCONS (no more MCS consoles)

2. Use only DASD (no more tapes)

3. Set up LOAD profiles on the HMC exclusively for standalone dump.

.
.
JO.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[EMAIL PROTECTED]


                                                                           
             Richard Bond                                                  
             <[EMAIL PROTECTED]>                                             
             Sent by: IBM                                               To 
             Mainframe                 [email protected]                
             Discussion List                                            cc 
             <[EMAIL PROTECTED]                                             
             .edu>                                                 Subject 
                                       Re: Stand alone Dump with ICC cards 
                                                                           
             03/20/2008 12:59                                              
             PM                                                            
                                                                           
                                                                           
             Please respond to                                             
               IBM Mainframe                                               
              Discussion List                                              
             <[EMAIL PROTECTED]                                             
                   .edu>                                                   
                                                                           
                                                                           




Don't know but why bother? I always use the SYSCONS (HMC operating system
messages) for standalone dump console - works great for me anyway.

Dick

>>> "Andy White" <[EMAIL PROTECTED]> 3/20/2008 9:49:38 AM >>>

Is anyone out there using ICC for a z/OS console. We are switching over
from our 3174's and started to use ICC consoles so I thought id ask our
operator  to do a SAD from it. The first problem I had was I didn't change
the SAD to use the new console (address 1300) I changed it had them we do
it but we get  a xwait on the emulator, like it cant find the console.

Here is what I have coded job ran with zero's, No wait state just sits
there the system

         AMDSADMP IPL=D3390,VOLSER=AVE3EC,                               X
               MINASID=ALL,             X
               DDSPROMPT=YES,    X
               OUTPUT=T1511,    X
               REUSEDS=CHOICE,    X
               CONSOLE=((1300,3278),(1310,3278))
         END

Is there anything that needs to be coded for a ICC type of console to do a
SAD? Thanks in advance.


Andy
Internet: Mailto:[EMAIL PROTECTED]

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html