Mark Pace wrote:
Yep - I had one setup and working.  Then I changed the name of my MANx
datasets, and then the message number changed!
Changed from using SYS1.MANx  datasets to SYS1.MISZOS.MANx it appears that
the dump message has changed!?!?!
From:
*IEE362A SMF ENTER DUMP FOR SYS1.MAN2 ON PCAT01

To:
*IEE391A SMF ENTER DUMP FOR DATA SET ON VOLSER PCAT01, 748
                 DSN=SYS1.MISZOS.MAN2


You could use the IEFU29 SMF exit for this rather than MPF.
If you really want to use MPF, you could issue a message
from IEFU29 that might be easier to work with.

--
Richard

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html