Hi,
        We run a simple MPF exit specified in MPFLST00 that sets a
couple of bits in the CTXT DSECT pointed to by R1 at entrance. We also
include COM='MN JOBNAMES,T' in COMMND00 to require that the IEF403I
message is produced at job startup (required by our job scheduler).
Everything worked fine until we upgraded from z/OS 1.7 to 1.9, at which
point an invocation of the exit would turn off the JOBNAMES switch and
the IEF403I message would stop. We could reset it manually, but the exit
would again turn it off. OK....so the CTXT DSECT in IEZVX100 (the only
DSECT in the code) must have changed and we are setting bits dealing
with JOBNAMES. I reassembled it, refreshed the link list, etc. and the
problem went away....good! However, trying to understand the problem, I
looked at the differences of the DSECT between z/OS 1.7 and
1.9 and there were indeed flags added dealing with JOBNAMES monitoring,
but the displacement within the control block of the bits we were
setting had not changed. So, being a short program, I compared the
reassembled load module with the 1999 load module that had been causing
the problem, and, except for differences in the load module headers
(assembler version, link date, etc), the code was EXACTLY THE SAME. What
am I missing? I know it is normal practice to reassemble exits with OS
upgrades, but I can't see how doing it in this case fixed the problem.
Is it more likely that reloading the module fixed a corrupted module in
core?

Here is the entire source:

STM   R14,R12,12(R13)            SAVE CALLERS REGS         
BASR  R12,0                      ESTABLISH MODULE BASE     
USING *,R12                        REGISTER                
L     R5,0(R1)                   ESTABLISH ADDRESSABILITY  
USING CTXT,R5                      TO THE CTXT             
OI    CTXTRFB2,CTXTRDTM           NO HARDCOPY/NO DISPLAY   
OI    CTXTERF3,CTXTESJL           SUPPRESS FROM JOBLOG     
OI    CTXTERF3,CTXTNWTP           SUPPRESS FROM WTP        
LM    R14,R12,12(R13)             RESTORE CALLERS REGISTERS
BR    R14                         RETURN TO CALLER
IEZVX100                                          

This is why I am coming to the gurus....Thanks.
George Sproull
  DECC Mechanicsburg GS4B14
  DSN 430-3525 Comm (717) 605-3525
  Cell (717) 773-3781
  [EMAIL PROTECTED] 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html