In a message dated 6/12/2008 12:26:52 P.M. Central Daylight Time,  
[EMAIL PROTECTED] writes:

The vvds entry should contain the catalog where the dataset(s)  is
cataloged.


>>
It's sort of like a mystery novel(or  misery as the case may be).
 
-Usually start with ===>LISTC ent('hlq')  all
to see where the associations  are
-Then ===>LISTC ENT('UCAT')  all
to see the associations have a  home
-Probably a batch DIAGNOSE against the VOLUME  and UCAT
-ADRDSSU against the VVDS then Find on  DSN and see where
 it thinks the associations  are.
-If there's a match and not multivolume should  be able to RECAT
-If there's mismatch the Managing Catalogs  suggests using parm
    of CAT('MCAT_Name') to  bypass the check on the DELETE.    