On Sat, 21 Jun 2008 02:10:06 +0000, Ted MacNEIL <[EMAIL PROTECTED]> wrote:

>>Because we exclude--or rather don't include--SYSIKJUA in the conversion to
SYSTEMS scope, I can logon to other members of this sysplex with the same
>userid. We also tell JES2 to allow multiple TSO logon, but the whole
solution requires both GRS and JES2 changes. Plus accommodations for
conflicting data sets.
>
>We changed nothing when we upgraded from 2.10 to 1.4.
>It jest grew.
>I was the first to find it out, with an ISPPROF ENQ issue.
>

z/OS 1.4 was the release the IBM remove the check from JES2.  The
SYSIKJUA issue still exists.  Perhaps you already didn't propagate the
ENQ via GRS / MIM?

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - ZFUS G-ITO
mailto:[EMAIL PROTECTED]
z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to