Again,  referencing (0) is *not* the problem.  That works fine on most
GDGs.   The error seems specific to some GDGs, where *no* relative reference
works, even though there are several G000V00 generations cataloged.



On Tue, Sep 9, 2008 at 8:14 AM, J R <[EMAIL PROTECTED]> wrote:

> > It is my understanding that (0) never works with NEW.
>
> What you're saying seems reasonable, yet the JCL User's
> Guide has an example under "Generations of a Generation
> Data Group" to the contrary:
>
> //NEWGDS DD DSNAME=GDS(0),DISP=(NEW,CATLG,DELETE),
> // UNIT=3380,VOLUME=SER=334455,SPACE=(CYL,20)
>
>
> > Date: Tue, 9 Sep 2008 12:46:38 +0000
> > From: [EMAIL PROTECTED]
> > Subject: Re: BPXWDYN relative GDG reference error
> > To: [email protected]
> >
> > >In other words, perhaps no GDS entries exist for that particular GDG,
> and in that case generation 0 would work only with DISP=NEW.
> >
> > It is my understanding that (0) never works with NEW.
> >
> > -
> > Too busy driving to stop for gas!
>
>
>
> _________________________________________________________________
> Get more out of the Web. Learn 10 hidden secrets of Windows Live.
>
> http://windowslive.com/connect/post/jamiethomson.spaces.live.com-Blog-cns!550F681DAD532637!5295.entry?ocid=TXT_TAGLM_WL_domore_092008<http://windowslive.com/connect/post/jamiethomson.spaces.live.com-Blog-cns%21550F681DAD532637%215295.entry?ocid=TXT_TAGLM_WL_domore_092008>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
>
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to