On Thu, 30 Oct 2008 10:12:06 +0800, Tommy Tsui wrote: > After I try to activiate the CBU from 2094-401 to 2094-707, the LPAR >cannot be IPL successfully because of 878 until I set the INITSQA. Is there >any overhead while CBU activiated? How comes we need to add the default >SQA/ESQA to NIP processing after CBU activiated?
Look at last section of the Apar II12396: EXHAUSTION OF INITIAL SQA ESQA AFTER IODF CHANGES, MIGRATION TO Z/OS 1.8 OR LATER, OR MIGRATION TO Z/OS 1.9 OR LATER Did the number of (logical) processors for the LPAR grow after CBU? Theoretically: more processor power ---> more parallelism ---> more SQA needed... That was the key note of the explanation we have got. -- Zaromil ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html