Hello list,

I had the following question in July of this year.  I just want add to the 
archive the resolution of this problem.

<Snip from July 2008>

Our system is a 2096 U03 with three LPARs but no sysplex.  Two LPARs are 
production, one at z/OS 1.4 and a small one at z/OS 1.7. The current IODF 
is 
a version 5 level.

This weekend I activated a new IODF on the 1.4 system using the HCD 
dialogs 
which completed successfully. I did not do an activate on the 1.7  We then 

IPLed the 1.4 system and it just waited.  The NIP console was not 
activated 
and there was not a hard wait. I brought up my rescue system and changed 
the IODF back to the old one and the 1.4 system IPLed ok. 

<end of snip>

The problem was I had two control unit # 2 on the same path because I did 
not requested EMC to verify my IODF.  HCD did not object because it had to 
do with the DMX1000 internal mapping of CHIPIDs.  This obviously caused 
the DMX1000 to do some sort of diagnostics.  My IODF error was partially 
due to the fact that our maintenance contract had expired with EMC and we 
had not completed negotiations with a third party to support the DMX1000.

Regards,