On Mon, 24 Nov 2008 12:09:20 -0500, Dean Montevago wrote: >YES ! Thanks Mark. > >-----Original Message----- >From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On >Behalf Of Mark Zelden >> >>GIM54701S ** ALLOCATION FAILED FOR SMPLTS - IKJ56864I UTILITY DATA SET >>NOT >> ALLOCATED, USER NOT AUTHORIZED FOR FUNCTION SPECIFIED. > >You have a JOBLIB/STEPLIB for SMP/E or perhaps HLASM and it is not APF >authorized. Either remove them if the LNKLST levels are ok or APF >authorize them. > I would have guessed from the IKJ56864I that SMPLTS was RACF protected, and that the programmer was running SMP/E from a user ID not authorized to access SMPLTS. In that case, I would have expected SMP/E to perform SAF checking to assure that a user not properly authorized does not access SMPLTS. Where is the flaw in my reasoning?
Oops; I remember. BTDT. It's the WAIT problem. When necessary, I've dealt with this by removing the WAIT operand. It's a major discourtesy that IKJ56864I doesn't provide better information concerning the "FUNCTION SPECIFIED". -- gil ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html