Ted MacNEIL pisze:
we flashcopy volumes for clone subsytem purposes, and PPRC for D/R purposes - but our storage folks tell us that it is difficult to PPRC
flashcopy *target* volumes

That is not the design.

You PPRC then you FlashCopy.
Not, the other way around.
FlashCopy Target Volumes are off-line.

There are many ways to skin a cat. You can Flashcopy first and then PPRC it. Or flashcopy and PPRC from same source (set of volumes).
Or establish PPRC pairs then Flashcopy from target.
I would first ask what the needs are and what are the resources available (disk space at both sides, licenses). Then try to adjust method.