On Fri, 23 Jan 2009 16:24:40 -0600, Larre Shiller wrote:
>
>I believe that is because SMP/E does not OPEN the data sets for an APPLY
>CHECK.  That's why an APPLY CHECK can end with a CC 0, yet when the
>SYSMODs are actually applied, the data set can run out of directory blocks or
>space and the APPLY will fail.
>
I believe it does allocate them (or discover them to be allocated
by JCL) though, and this operation could (should?) be reported
in SMPRPT.

Space problems are a different matter, and it's unreasonable to
expect APPLY CHECK to predict them.

-- gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html