Thanks for the quick reply. In reading defining mcs consoles to cics it says
to give it the 8 character name of the console from the consolxx parmlib
member. But in the mvs init and tuning guide it said the name could be 2-8
characters so I only made it 7. Is cics going to regurgitate the 7 character
master console name wanting 8 characters??thx
Mace

On Thu, Feb 12, 2009 at 10:35 AM, Brian Peterson <
[email protected]> wrote:

> I would suggest that you check the console names you've given your new
> consoles, and compare them to the names you used previously.  The console
> name I'm talking about is the NAME parameter of the CONSOLE statement in
> SYS1.PARMLIB(CONSOLnn).
>
> Maybe you gave your new ICC consoles new names, and didn't define those
> console names to CICS....
>
> Brian
>
> On Thu, 12 Feb 2009 08:25:34 -0600, Larry Macioce wrote:
>
> >We have just moved our consoles from 3x74 to osa-icc connection.
> >We ipled for the first time last night an I got a call that cics didn't
> recognize
> >the consoles.
> >Can any one help me in the definiton of this type of console? In the iocds
> they
> >are defined as 3270-x, is this the only change I'll need in cics? It has
> been
> >awhile since I added the origianal consoles and in looking around I am
> lost.
> >Any help is great appreciated
> >thanks
> >mace
> >
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to