We are trying to insert a server/pak tape 3592 into our TS3500 library, and the 
accessor is picking it up without a barcode.  We followed the manual (redbook), 
 and the accessor should not pick it up.  Do we need to set something in the 
box?  Thank you.


Inserting cartridges without a barcode label
You might receive cartridges from a software vendor, another company, or even 
from IBM
that have standard label (SL) formats but no barcode labels. This special 
situation needs a
particular procedure. The following example describes the insertion of a 
cartridge with an SL
of YX0100:
1. First, you must verify that this VOLSER is not defined within a VOLSER range 
in the
TS3500.
2. Insert the cartridge in the entry station. The accessor will not pick the 
cartridge because of
the missing barcode.
3. Use your Web specialist function to select Manage Cartridges → I/O Station.
You will see only one cartridge with unknown status.
4. Select the cartridge and select Fix Unknown Volume Serial.
5. Enter VOLSER=YX0100 and the type (JA, JJ, and so forth).


Sharon Lopez
Enterprise z/OS Systems Programmer
State of North Carolina
Office of Information Technology Services
919-754-6432     Office
919-398-8638 Cell
919-850-2854  Fax
919-754-6000 ITS Service Desk
<mailto:z...@its.nc.gov>
sharon.lo...@its.nc.gov<mailto:sharon.lo...@its.nc.gov>
http://www.its.state.nc.us<http://www.its.state.nc.us>