On Sun, 22 Mar 2009 11:55:17 -0400, Stephen McColley <[email protected]>
wrote:

> Other interesting
>features allow you to limit the number of jobs that can start in a given
>job class for a single system within a MAS - JES2 only allows you to set
>a max for the MAS, 

That hasn't been true since z/OS 1.8.  See XEQMEMBER in the JOBCLASS
definition.

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - ZFUS G-ITO
mailto:[email protected]
z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to