On Sun, 22 Mar 2009 11:55:17 -0400, Stephen McColley <[email protected]> wrote:
> Other interesting >features allow you to limit the number of jobs that can start in a given >job class for a single system within a MAS - JES2 only allows you to set >a max for the MAS, That hasn't been true since z/OS 1.8. See XEQMEMBER in the JOBCLASS definition. Mark -- Mark Zelden Sr. Software and Systems Architect - z/OS Team Lead Zurich North America / Farmers Insurance Group - ZFUS G-ITO mailto:[email protected] z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/ Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html