In a message dated 3/30/2009 6:48:26 A.M. Central Daylight Time,  
[email protected] writes:

1. Prepare IOCDS (text file)
2. Run ICKDSF standalone program (from  tape) - init some devices.
3. Run ADRDSSU SA restore (from tape) - restore  Driver
4. Run Driver, log on to TSO start working - now you have z/OS which  can 
be a driver.
5. Run normal ServerPac procedure.


>>
This is a good exercise for Cold Site planning  as well.
 
1)From SE use stand-alone IOCP to import text  and make IOCDS
  that defines basic system of tapes,  dasd and consoles to run
  the driver  system.
 
2)Have to configure the DASD subsystem to make  them available for INIT. 
Similarly for tape, get the CHIPids, devices, and  features lined up to match. 
Initially can use HMC for console but  for external need to be configured and 
IML'd  to READY.
 
3)Now can IPL ICKDSF tape and make DASD MVS aware.
 
4)IIRC driver can be ADRDSSF or FDR format depending on order options.  
Restore the driving system and IPL from device resvol is restored to.
 
5)If all the jots and tittles are crossed should have a working system to  
continue the build process. 