Laine, Rogers pisze:
We are looking to install two OSA cards to support two ICC OSC ports to
handle our remote consoles.
We have a z890 installed and my concern is when the CE applies
maintenance to the OSC will this interrupt these active consoles?
Are these OCS ports handled any differently from the OSD's in regard to
maintenance by CE?
Since I will have two OSC I can plan for the outage (if it exists) on
one while running off the other.

You will have an outage.
However:
1. You can decide when it happens.
2. You want to have 2 OSC chpids. In this case you can define 2 sets of console/terminal sessions and simply change the consoles.
Short procedure:
on every LPAR console A is currently in use
on every LPAR start console B session (VARY ccuu,console is needed)
on every LPAR switch master console to B (VARY ccuu,mstcons) - things changed since zOS 1.9
on every LPAR switch A console offline (VARY ccuuA,OFFLINE)
...and vice versa.

--
Radoslaw Skorupka
Lodz, Poland


--
BRE Bank SA
ul. Senatorska 18
00-950 Warszawa
www.brebank.pl

Sd Rejonowy dla m. st. Warszawy XII Wydzia Gospodarczy Krajowego Rejestru Sdowego, nr rejestru przedsibiorców KRS 0000025237
NIP: 526-021-50-88
Wedug stanu na dzie 01.01.2009 r. kapita zakadowy BRE Banku SA (w caoci 
wpacony) wynosi 118.763.528 zotych. W zwizku z realizacj warunkowego 
podwyszenia kapitau zakadowego, na podstawie uchway XXI WZ z dnia 16 marca 
2008r., oraz uchway XVI NWZ z dnia 27 padziernika 2008r., moe ulec 
podwyszeniu do kwoty 123.763.528 z. Akcje w podwyszonym kapitale zakadowym 
BRE Banku SA bd w caoci opacone.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to