The use of IEFUSI is intended to be a trigger. This is to force invoke
IEFUTL at an interval so that elapsed time can be calculated. If the
elapsed time calc in IEFUTL indicates, for example, 10 miniutes elapsed,
set the IEFUTL retcode to extend the job. If it indicates 2 hrs & 1
minute elapsed, allow the job to abend.

This will not be precise, but it will be close. Feel free to contact me
off list if you like.

HTH,

<snip>
> Code/install IEFUSI to limit *ALL* test jobs to (e.g.) 5 min of cpu
> time. Code/install IEFUTL to calc elapsed time and extend (or not) as
> required. IIRC, All of the required info needed should be available to
> the exit
> 
> Adjust CPU time limit to desired granularity based on your shop. Not
too
> precise but it should come close to your needs.
> 
> HTH,
> 

Problem: I must restict WALL CLOCK or ELAPSED time, not CPU used time.  
It's a weird political thing.
</snip>

----------------------------------------------------------------------