Thanks for that heads-up, Otto.

Bob

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Schumacher, Otto
Sent: Thursday, April 30, 2009 10:30 AM
To: [email protected]
Subject: Re: CF Level Considerations at DR

Depending on the level we had to increase the size of the structures for
CICS log and shunt before the regions would come back up. 

Regards 

Otto Schumacher 
Technical  Support, CICS

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Richards, Robert B.
Sent: Thursday, April 30, 2009 10:21 AM
To: [email protected]
Subject: CF Level Considerations at DR

Does anyone have any experience or considerations with having a higher
CF Level at your primary site than at the disaster recovery site? Are
there any issues I should be aware of?

Due to implementing STP here, we are fairly current and may be at a
higher level than our DR provider has installed. I am already planning
to use SIMETRID for the CLOCK00 stuff as we are going to be on one
machine there and are dropping the Sysplex Timers.


Bob  

 

----------------------------------------------------------------------