After you made the change in CONSOLxx to LOGON(AUTO) was there a plex wide IPL?

IIRC CONSOLxx definitions are plex wide so a member entering the plex will use 
a 'cached' version which may be different than you expect.

You should be able to dynamically alter to LOGON(AUTO) then as long as CONSOLxx 
matches the next IPL should be OK. 

-----Original Message-----
Allan Boyles

Well, this does not seem to be the explaination to our situation. 
- none of the systems in the sysplex are running 1.10 yet.
- LOGON(AUTO) is explicitly set for all MSCs in all the console members
- the D C command shows different results regarding LOGON= when issued from 
different Lpars. For some consoles LOGON=OPTIONAL shows up.

Regards,
Allan  

-----Ursprüngliche Nachricht-----
David Waldman

ERROR DESCRIPTION:
  When no specific LOGON attribute has been specified on the
  CONSOLE statement for a console, LOGON=OPTIONAL may appear in
  message CNZ4100I in response to a DISPLAY CONSOLES command
  regardless of the LOGON attribute specified for the DEFAULT
  statement in CONSOLXX.
  This problem occurs in shared mode for consoles active on
  systems running z/OS R10. If the R10 system where the consoles
  are active is not running in a sysplex, LOGON=OPTIONAL is
  always displayed for the active consoles. If the R10 system
  where the consoles are active is running in a sysplex and an
  APPLID is not specified on the INIT statement in CONSOLxx,
  LOGON=OPTIONAL is displayed for the active consoles from the
  time the system is IPL'd up until when the next system is IPL'd
  into the plex.
 
 
  LOCAL FIX:
  Define LOGON attribute for individual consoles.

hth,
Dave


>
>For all the MCS consoles in a Sysplex we have the LOGON(AUTO) parameter
set on all Lpars. When issuing the D C command on various Lpars the display 
shows "LOGON=OPTIONAL" for some systems. The display is reflected correctly for 
the Lpars own consoles, ie. the consoles defined on the system where the 
command is issued.
>Can anyone explain this?
>Kind regards,
>
>Allan Boyles
>

----------------------------------------------------------------------