Wayne Driscoll/Chicago/i...@ibmus wrote on 05/27/2009 03:30:23 PM:
> Look up the STORAGE macro in the Assembler Services Reference, It
> provides services similar to GETMAIN/FREEMAIN, but via a PC routine as
> opposed to an SVC.
SVC and branch entry to VSM services are available via the
STORAGE macro by specifying
LINKAGE=SYSTEM|SVC|BRANCH|GLOBALBRANCH
Newer parameters are available only on the STORAGE
macro, and not GETMAIN. For example:
BACK=BYSPT|NONE|ALL
FIX=NONE|SHORT|LONG
OWNERASID=DECIMAL NUMBER|REGISTER(2)-(12)
| RS-TYPE ADDRESS>
Jim Mulder z/OS System Test IBM Corp. Poughkeepsie, NY
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO