Audit the SMTP stc userid and then look in SMF. No better way.

Itschak

On Thu, Jun 4, 2009 at 1:32 PM, Jorge Garcia <jgarc...@mapfre.com> wrote:

> Hello:
>
>  We need to send a STC sysout by SMTP and we leave this sysout in Q class
> in the spool (the class isn't important).
> When the SMTP STC try to process this sysout this message appears:
>
> $HASP186 HZSPRINT OUTGRP=2.1.1 NOT SELECTED BY STC08510/SMTP.SMTP
> DUE
> 721
>         TO SECURITY POLICY
>
> The STC SMTP starts with STCSYS group and the access in RACF access list
> in the JESSPOOL class is ALTER (like the manual says).
>
> Is necessary another access to this class?. What's wrong with it?.
>
> Thanks
>
> Jorge García Juanino
> Técnico de Sistemas Z/Os
> DGTP Departamento de Técnica de Sistemas
> MAPFRE
> Crtra. De Pozuelo nº 52