Look in the MVS System Codes document. Fnn are issued for errors detected in SVC nn (nn = X'D6' = 214)
So you have an error from SVC 214. SVCs > 199 are typically USER SVCS. Figure out who provided this SVC and contact them for support. Alan -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Subject: What is System Completion Code FD6? I have tried Google and Quick-Ref, and come up empty here. How can I track down what this means and how to fix it? Thanks! Don Johnson CA Sr. Support Engineer Email [email protected] ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html