On 6/25/2012 3:56 PM, Chuck Arney wrote:
Thanks for the suggestions John, but I don't find an IDCAMS ALTER parameter
that allows you to modify the hex device type code for a nonvsam catalog
entry. Am I looking in the wrong place or are you dreaming of the way "it
should be"?
I'd prefer to use something like you suggest but I fail to see a way to make
it work.
I don't think you can change this with an ALTER, the last time I
did this, I used DELETE NOSCR and DEFINE. It might help to turn off
the CATALOG SMF records during this processing. If you have
a vendor utility like Skip had, that is probably the best
approach.
--
Richard
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN