While I can't say anything specific about your system, my own observations on
two independent systems [One at 1.11 and the other at 1.12] indicates an error
in IEEACTRT in SYS1.SAMPLIB.
In the 1.11 version the following code occurs (NOTE SMF30SRB_L is used).
LG R01,SMF30SRB_L GET SERVICE UNITS USED @P6C 03590035
BAL R14,PCOUNT2 CALL CONVERT ROUTINE @P6C 03600033
In the 1.12 version the code is (NOTE SMF30SRV_L is used):
LG R01,SMF30SRV_L GET SERVICE UNITS USED @P7C
BAL R14,PCOUNT2 CALL CONVERT ROUTINE @P6C
The latter version is correct and indicates TOTAL service used, while the
previous only indicates SRB service used. That would account for the
discrepancy in the reporting between the two releases.
As I said, I can't say that this is your specific problem, but it would be
worth confirming that your IEEACTRT routine is correct.