A.Cecelio,
 For the rmm system, you do not need to write any code/rexx, simply run EDGHSKP 
utility with PARM='CATSYNCH,VERIFY'.
rmm will assume you have catalogs fully shared and will cross-check all your 
connected ICF catalogs with the rmm CDS data set records. rmm reports 
mismatches, and, because you run with VERIFY, will also report all data sets in 
the catalog on tape that are not defined to rmm.

On your non-rmm system - it would be quicker to convert the existing tape 
systems' data base to rmm CDS, run rmm in parallel, using CATSYNCH,VERIFY to 
get the comparison, than to write your own tool........

Mike Wood  :: rmm expert

----------------------------------------------------------------------