Jim,
Your suggestion almost worked. Neither the home or primary AS alone were
enough to cause the slip to fire. I found the cross memory IF slip fired only
if I added BOTH asids to the slip as follows -
SLIP SET,IF,ID=RJM1,ACTION=SVCD,ASID=(asid-of-STC2. asid-of-STC1),
PVTMOD=(module,offset,offset),END
This could get complex as there are quite a few different home ASs that can PC
into the single primary AS, I guess I can just add them all to the ASID list?
Does that mean if I have say a singal primary and 5 possible home ASs listed it
will dump all 6 or just the hone and primary at the time of the slip?
Thanks for the pointer in the right direction.
Ron.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN