In <[email protected]>, on 12/05/2012
at 06:36 AM, Paul Gilmartin <[email protected]> said:
>How does STOP work? Is MODIFY similar?
Almost identical; both chain a new CIB to the CSCB and post an ECB.
The differences are:
1. ECB CC
2. CIB verb
3. No text from STOP command
>Does either schedule an RB to a task?
No.
>Which is older, STOP or MODIFY?
They are essentially contemporaneous; certainly both arrived in the
mid 1960's.
--
Shmuel (Seymour J.) Metz, SysProg and JOAT
Atid/2 <http://patriot.net/~shmuel>
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN