In <[email protected]>, on 12/05/2012
   at 06:36 AM, Paul Gilmartin <[email protected]> said:

>How does STOP work?  Is MODIFY similar?

Almost identical; both chain a new CIB to the CSCB and post an ECB.
The differences are:

 1. ECB CC
 2. CIB verb
 3. No text from STOP command

>Does either schedule an RB to a task? 

No.

>Which is older, STOP or MODIFY?

They are essentially contemporaneous; certainly both arrived in the
mid 1960's. 

-- 
     Shmuel (Seymour J.) Metz, SysProg and JOAT
     Atid/2        <http://patriot.net/~shmuel>
We don't care. We don't have to care, we're Congress.