Hello Mike,
probl overcomed by executing the following cmds:

1) DElete OSFORMAT VTOC
//STEP1  EXEC PGM=ICKDSF,REGION=4M
//SYSPRINT DD  SYSOUT=*
//INVOL1   DD  UNIT=(3390,,DEFER),VOL=(PRIVATE,SER=XXX248),
//         DSN=SYS1.VTOCIX.XXX248,DISP=(OLD,DELETE)
//SYSIN    DD    *
 BUILDIX DDNAME(INVOL1) IXVTOC
/*

2) Create IXFORMAT
//STEP1  EXEC PGM=ICKDSF,REGION=4M
//SYSPRINT DD  SYSOUT=*
//INVOL1   DD  UNIT=(3390,,DEFER),VOL=(PRIVATE,SER=XXX248),
//         DSN=SYS1.VTOCIX.XXX248,DISP=(NEW,KEEP),
//         SPACE=(TRK,178,,CONTIG)
//SYSIN    DD    *
 BUILDIX DDNAME(INVOL1) IXVTOC
/*
and I got:
ICK03091I EXISTING VOLUME SERIAL READ = XXX248
ICK01503I 177E REQUEST RECEIVED TO CONVERT VTOC TO IXFORMAT
ICK01504I 177E VTOC FORMAT IS CURRENTLY OSFORMAT, REQUEST ACCEPTED
ICK01508A 177E SHOULD CONVERSION PROCEED? REPLY U TO CONTINUE, ELSE T
ICK01513I 177E  BUILDIX PROCESSING COMPLETED:  VTOC IS NOW IN IXFORMAT
ICK01317I VTOC-INDEX IS LOCATED AT CCHH=X'1D61 0000' AND IS   178 TRACKS.
          17:37:01    12/06/12

ICKDSF - MVS/ESA    DEVICE SUPPORT FACILITIES 17.0

Many thx Mike, A.Cecilio.


On Thu, Dec 6, 2012 at 5:18 PM, Mike Schwab <[email protected]> wrote:

> This is a working example, with an EXISTING VTOCIX.
> ADD allocation if you need to CREATE the VTOCIX.
> The Parm avoids the ICK01508A message, need verify for some functions.
>
> //BLDIX    EXEC PGM=ICKDSF,PARM='NOREPLYU'
> //LGK034   DD   DSN=SYS1.VTOCIX.LGK034,DISP=(OLD),
> //             VOL=(PRIVATE,SER=LGK034),UNIT=(DISK,,DEFER)
> //SYSPRINT DD  SYSOUT=*
> //SYSIN    DD  *
>  BUILDIX DDNAME(LGK034) IX
>
> On Thu, Dec 6, 2012 at 11:10 AM, af dc <[email protected]> wrote:
> > Hello,
> > I'm having this probl:
> > ICK03091I EXISTING VOLUME SERIAL READ = XXX248
> > ICK01503I 177E REQUEST RECEIVED TO CONVERT VTOC TO IXFORMAT
> > ICK01504I 177E VTOC FORMAT IS CURRENTLY OSFORMAT, REQUEST ACCEPTED
> > ICK01508A 177E SHOULD CONVERSION PROCEED? REPLY U TO CONTINUE, ELSE T
> > ICK31511I 177E CVAF ERROR: RETURN CODE= 00   ERROR CONDITION= 027
> > ICK31515I 177E BUILDIX COMMAND FAILED.
> >           17:07:41    12/06/12
> >
> > how can I overcome this ?? do I need XXX248 offline ??
> >
> > Any hint is appreciated asap.
> >
> > Many thx, A.Cecilio.
>
> --
> Mike A Schwab, Springfield IL USA
> Where do Forest Rangers go to get away from it all?
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to