I know that this is not the RACF list, but I am not subscribed there, so I am 
hoping that someone can tell me what to do. I am reluctant to make changes in 
that class - if I am wrong, then I cannot get into my telnet session anymore 
because OMVS/TCPIP might have severe problems.

ADCD 1.13 system. 
SETROPTS LIST                                                               
ATTRIBUTES = INITSTATS WHEN(PROGRAM -- BASIC)                               
ACTIVE CLASSES = DATASET USER GROUP ACCTNUM AIMS CBIND CDT CIMS DIMS DSNR   
                 EJBROLE FACILITY GEJBROLE GIMS GXFACILI IIMS JIMS LIMS     
                 LOGSTRM MIMS PTKTDATA PTKTVAL RIMS SERVAUTH SERVER STARTED 
                 SURROGAT TIMS TSOAUTH TSOPROC UNIXPRIV XFACILIT
The book says that WHEN(PROGRAM) is always active in basic mode when 
FACILITY/IRR.PGMSECURITY is not defined. It is not defined. Would I also see 
PROGRAM under active classes or is class PROGRAM simply not active? In other 
words, are the definitions made in that class actually used? (I know I could 
test by activating enhanced-warning mode, but don't really want to dive deeper 
into this than necessary.)

This was defined in 1996 (showing the ADDMEM part):
0503 *        PROGRAM  CEE.SCEERUN2    
0503 *        PROGRAM  TCPIP.SEZALOAD  
0503 *        PROGRAM  SYS1.SIEALNKE   
0503 *        PROGRAM  SYS1.CSSLIB     
0503 *        PROGRAM  TCPIP.SEZALPA   
0503 *        PROGRAM  TCPIP.SEZALINK  
0503 *        PROGRAM  SYS1.LINKLIB    
0503 *        PROGRAM  CBC.SCLBDLL     
0503 *        PROGRAM  CEE.SCEERUN     
0503 *        PROGRAM  SYS1.SCEERUN    
0503 BPXBINIT PROGRAM  SYS1.LINKLIB    
0503 BPXEV003 PROGRAM  SYS1.LINKLIB    
0503 BPXOLVD  PROGRAM  SYS1.LINKLIB    
0503 BPXOV    PROGRAM  SYS1.LINKLIB    
0503 BPXPLPKA PROGRAM  SYS1.LINKLIB    
0503 BPXUCSNM PROGRAM  SYS1.LINKLIB    
0503 BPXUEYI1 PROGRAM  SYS1.LINKLIB    
0503 BPXUI1EY PROGRAM  SYS1.LINKLIB    
0503 BPXZ24   PROGRAM  SYS1.LINKLIB    
0503 RLOGIND  PROGRAM  SYS1.LINKLIB    

If I read the book right (and the answer above is yes, they are used), then for 
sys1.linklib profile * will be used (and not the specific program names, never 
mind that there isn't any program named BPXOV in sys1.linklib these days). In 
other words, for sys1.linklib all the profiles with 'real' program names are 
obsolete, right?

Thanks for any help before I shoot myself in the foot.
Barbara

ps: To answer Mike Schwabs question: Yes, I can sent my batch jobs to the 
cbttape once I am done.

----------------------------------------------------------------------