I never saw a reply to Lizette's post. We also have an interest in the 
same topic. We want to encourage members of the technical staff to manage 
our sandbox LPARs rather than pester--er, request--Operations to shut 
down/IPL systems that 'we' own. The problem is how to allow these folks to 
manage sandbox LPARs only. Using our fine automation product together with 
the V XCF...REIPL command, they can reIPL a system on their own. Or we can 
write our own IPL command that does a SAF check before calling BCPII to do 
the deed. 

The difficulty occurs when a system is not currently running and/or when 
the sysres volume needs to be switched from its last used value to a 
different one. We have not found a way for BCPII to even query the current 
IPL profile, let alone switch to an alternate profile. Without this 
capability, we cannot insist that our folks do their own laundry. 

.
.
JO.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[email protected]



From:   Lizette Koehler <[email protected]>
To:     [email protected], 
Date:   12/06/2012 02:52 PM
Subject:        BCPII and activation profile
Sent by:        IBM Mainframe Discussion List <[email protected]>



I have a friend who is wondering if there examples of a HWI BCPII that can 
alter the activation profile.

He has some ec12s, and z114s, on z/OS V1.13  -  Fairly current on most 
hardware as they have recently gone through a hardware upgrade which 
includes DS800's.

Thanks

Lizette


----------------------------------------------------------------------