Did someone commit adultery with either proc RMFM3B or CLIST/EXEC RMFM3B (or both)?
Tom Vacation Notice: None Tom Puddicombe Mainframe Performance & Capacity Planning CSC 31 Brookdale Rd, Meriden, CT 06450 ITIS | (860) 428-3252 | [email protected] | www.csc.com This is a PRIVATE message. If you are not the intended recipient, please delete without copying and kindly advise us by e-mail of the mistake in delivery. NOTE: Regardless of content, this e-mail shall not operate to bind CSC to any order or other contract unless pursuant to explicit written agreement or government initiative expressly permitting the use of e-mail for such purpose. From: "Donnelly, John" <[email protected]> To: [email protected] Date: 01/02/2013 04:16 PM Subject: RMF and ISFOUT Sent by: IBM Mainframe Discussion List <[email protected]> We have been executing an IBM process that collects "DA ALL" type system views for a long time. EDIT SYS1.PROCLIB(RMFM3B) - 01.00 Columns 00001 Command ===> Scroll === ****** ***************************** Top of Data *********************** 000050 //RMFM3B PROC RMF=SYS1,ISPF=SYS1,REPORT=WFEX,HLQ= 000051 //*************************************************************** 000052 //* 000053 //* PROPRIETARY STATEMENT: 000054 //* LICENSED MATERIALS - PROPERTY OF IBM 000055 //* "RESTRICTED MATERIALS OF IBM" 000056 //* 5694-A01 000057 //* COPYRIGHT IBM CORP. 1998, 2007 000058 //* STATUS=HRM7740 (Z/OS V1R9 RMF) 000059 //* 000060 //* DESCRIPTION: 000080 //* RMF MONITOR III REPORTER BACKGROUND SESSION 000100 //* PRODUCES FREE SELECTABLE REPORTS ACCORDINGLY 000200 //* TO THE &REPORT INPUT PARAMETER 000210 //* THE REPORT FREQUENCY DEPENDS ON THE MINTIME 000220 //* OPTION OF THE MONITOR III GATHERER (DEFAULT 100S) 000221 //* On 22DEC12 this started task abended with: IEC130I ISFOUT DD STATEMENT MISSING ISF037I SDSF SDUMP NOT TAKEN, SUPPRESSED BY DAE ISF012I SDSF ABEND USER 13 AT 11203582 IN MODULE ISFBDSP ISF013I SDSF ABEND R0-R7 80000000 8000000D 00000041 00000388 ISF014I SDSF ABEND R8-R15 11201BCC 11201AF8 11204318 00998730 IEA995I SYMPTOM DUMP OUTPUT 528 USER COMPLETION CODE=0013 We have been trying to find an environment change to explain this to no avail. Might someone have some insight into this situation? Thankyou John Donnelly Texas Instruments SVA 2900 Semiconductor Drive Santa Clara, CA 95051 408-721-5640 408-470-8364 Cell [email protected] ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
