The SMPPTS is a PDS file but still i get the same error message.
General Data Current Allocation
Management class . . : xxxxxx Allocated cylinders : 100
Storage class . . . : xxxxxx Allocated extents . : 1
Volume serial . . . : xxxxxx Maximum dir. blocks : 20
Device type . . . . : 3390
Data class . . . . . : xxxxx
Organization . . . : PO Current Utilization
Record format . . . : FB Used cylinders . . : 1
Record length . . . : 256 Used extents . . . : 1
Block size . . . . : 27904 Used dir. blocks . : 1
1st extent cylinders: 100 Number of members . : 5
Secondary cylinders : 50
Data set name type : PDS Dates
Creation date . . . : 2013/02/07
Referenced date . . : 2013/02/07
Expiration date . . : ***None***
On Thu, Feb 7, 2013 at 9:54 PM, Steve Thompson <[email protected]> wrote:
> From: "Staller, Allan" <[email protected]>
> Date: 02/07/2013 10:20 AM
>
>
> <SNIPPAGE>
> You have specified the SMPPTS (a PDS/PDSE) as sequential input. This
> means the "directory" of the PDS/PDSE is being read as a logical record.
> As we all know, the "logical record length" of a PDS directory entry is
> 256, not 80, hence your problem.
>
> <SNIP>
>
> Thank you, Allan. Much better answer than mine, because I got too close to
> the tree.... I was trying to figure this out using the diagnostic info
> presented with the infocenter based doc...
>
> Regards,
> Steve Thompson
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN