I'm trying to move several hundred UCBs to 31 bit storage. It can't be done 
dynamically since those devices are online to those systems.

Mark Jacobs

Sent from ProtonMail, Swiss-based encrypted email.

GPG Public Key - 
https://api.protonmail.ch/pks/lookup?op=get&[email protected]

‐‐‐‐‐‐‐ Original Message ‐‐‐‐‐‐‐
On Wednesday, May 20, 2020 10:59 AM, Jousma, David 
<[email protected]> wrote:

> What cannot be done dynamically? If not dynamic, then it sounds like a POR?
>
> Dave Jousma
> AVP | Manager, Systems Engineering 
>
> Fifth Third Bank  |  1830 East Paris Ave, SE  |  MD RSCB2H  |  Grand Rapids, 
> MI 49546
> 616.653.8429  |  fax: 616.653.2717
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [email protected] On Behalf Of 
> Mark Jacobs
>
> Sent: Wednesday, May 20, 2020 10:53 AM
> To: [email protected]
> Subject: IODF Activation Question
>
> CAUTION EXTERNAL EMAIL
>
> DO NOT open attachments or click on links from unknown senders or unexpected 
> emails
>
> We have 8 systems in a sysplex that share a single IODF dataset, all dynamic 
> IODF activation's occur in this sysplex. I'm looking to perform HCD changes 
> that can't be dynamically activated, each system will need to be IPLed with 
> the new IODF. Once I do so however, the hardware and software IODF will be 
> out of sync. How do I get them back in sync?
>
> Sent from ProtonMail, Swiss-based encrypted email.
>
> GPG Public Key - 
> https://protect2.fireeye.com/url?k=8ff4d39f-d3a82790-8ff4f907-0cc47a33347c-4e8b6fa59ed3960b&u=https://api.protonmail.ch/pks/lookup?op=get&[email protected]
>
> ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
>
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
> [email protected] with the message: INFO IBM-MAIN CAUTION EXTERNAL 
> EMAIL
>
> DO NOT open attachments or click on links from unknown senders or unexpected 
> emails
>
> This e-mail transmission contains information that is confidential and may be 
> privileged. It is intended only for the addressee(s) named above. If you 
> receive this e-mail in error, please do not read, copy or disseminate it in 
> any manner. If you are not the intended recipient, any disclosure, copying, 
> distribution or use of the contents of this information is prohibited. Please 
> reply to the message immediately by informing the sender that the message was 
> misdirected. After replying, please erase it from your computer system. Your 
> assistance in correcting this error is appreciated.
>
>
> -----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
>
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to