More precisely, when  ADRDSSU, initializes a volume, it writes
IPL text whose only purpose is to load a 00F wait state.  So if you 
do not replace that with IPL text for another program, you get a 00F wait 
state when you IPL that volume. 

Jim Mulder z/OS Diagnosis, Design, Development, Test  IBM Corp. 
Poughkeepsie NY


"IBM Mainframe Discussion List" <[email protected]> wrote on 
05/21/2020 09:50:59 AM:

> From: "Jordi Bornay" <[email protected]>
> To: [email protected]
> Date: 05/21/2020 12:37 PM
> Subject: Re: How to configure LOADxx in DR
> Sent by: "IBM Mainframe Discussion List" <[email protected]>
> 
> yes, but the error that comments (00F) is because it cannot find theIPL 
text.
> 



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to