Tony to answer your questions.  In this shop a MOD-27 is 32,760 cyls and a 
MOD-54 is 65,520 cyls.  As for how they are allocated, that I can't answer.  We 
don't have IBM DASD and the vendor we have does the configuration based on what 
we ask for.  Just to round things out the EAVs we do have are 1,177,554 cyls.


Thanks..

Paul Feller
GTS Mainframe Technical Support

-----Original Message-----
From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of 
Seymour J Metz
Sent: Thursday, July 02, 2020 6:12 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: What is the real size of a 3390-27 and 3390-54 [EXTERNAL]

Keep in mind that you are dealing with virtual DASD. There never was a 3390 
model 27 or 54, so DASD providers are free to use whatever sizes tey want. 
Using 3 times a model 9 capacity and 6 times a model 9 capacity is 
conventional, but there's noting wrong with using a slightly larger size. There 
is no architectural limit on a 3390-27, but if you're going to use a size 
larger than 32760 then it must be an EAV.


--
Shmuel (Seymour J.) Metz
https://urldefense.proofpoint.com/v2/url?u=http-3A__mason.gmu.edu_-7Esmetz3&d=DwIFAg&c=9g4MJkl2VjLjS6R4ei18BA&r=eUhu3PeeWy6RTndlJVKembFjFsvwCa8eeU_gm45NyOc&m=3g-wCGqKzy3im7XztVXg9Q9xNMtTbsrKV7VtsDUYL2k&s=Z9efFPF85QAkL5KSSAa5qUlO4Yr5lWD71KPaFqeL9To&e=
 

________________________________________
From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of 
Tony Thigpen [t...@vse2pdf.com]
Sent: Thursday, July 2, 2020 5:51 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: What is the real size of a 3390-27 and 3390-54

I am seeing some DS8000s where a mod-27 is defined as 30051 cylinders. I am 
seeing other sites were the mod-27 is defined with 32760 cylinders.

I know the architectural limit of a mod-27 is 32760 cylinders, but if you work 
with multiples of mod-1 units, the 30051 number make sense.

I also know that when you use the DSCLI, you can specify any number of 
cylinders. What I don't know is what the old GUI did.

So, some questions:

1) What size is a mod-27 in your shop?
2) Was your DASD allocated using the DSCLI or the GUI?

--
Tony Thigpen

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
Please note:  This message originated outside your organization. Please use 
caution when opening links or attachments.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to