tor 2020-07-16 klockan 07:28 +0000 skrev Gadi Ben-Avi: > Hi, > > I was asked to make sure that the mainframes are using the same time > source as the rest of the computers on our network. > I know what the NTP servers are in our network. > > In the HMC, I found 'Customize Console Date/Time' > I added the NTP servers to the screen, and they seem to have been > accepted. > (I did this for our DR computer) > > Do I have to do anything else? > > We are currently running z13s's if that matters. >
You need at least three time sources, the more the better. The time sources you have, what stratum are they at (stratum = how far from a time source which they are.) Verify that your organization's time sources is independent of each other (a lot of people fails at that...) Can the CPC be a time source for other system ie can it be a server in ntp parlance ? Can the CPC be added as a peer ? Would it be feasible to run the z13s as time servers in a peering agreement which each other ? ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN