Thank you. So simple.
It worked without the -.

On Tue, Sep 8, 2020 at 10:52 AM Cieri, Anthony <
[email protected]> wrote:

>
>         Try it without the '-'.   I.E.  //FTPS   PROC
> MODULE='FTPD',PARMS='Port 9921'
>
>
>
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On Behalf
> Of Roberto Halais
> Sent: Tuesday, September 08, 2020 10:48 AM
> To: [email protected]
> Subject: New listening port for ftp
>
> [[ SEI WARNING *** This email was sent from an external source. Do not
> open attachments or click on links from unknown or suspicious senders. ***
> ]]
>
>
> Listers:
>
> I am implementing a second FTP stc and I want it to listen on port 9921.
>
> The FTPD proc listens on port 21 by default.
>
> I read somewhere that you could specify //FTPS EXEC PGM=FTPD,PARM=(-PORT
> 9921)
> but I get: CEE3611I The run-time option -PORT was an invalid run-time
> option.
>
> How do I specify a different listening port for the stc?
>
> Couldn't find documentation on it.
>
> Thank you for any hints.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>


-- 
Politics: Poli (many) - tics (blood sucking parasites)

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to