I can reproduce this with: PP 5655-EC6 IBM Enterprise COBOL for z/OS 6.1.0 P180612
Peter On Fri, 2 Oct 2020 at 00:46, Charles Mills <[email protected]> wrote: > It appears to me that COBOL 6.2 or 6.3 fails a BASIS statement if there is > any COPYLOC in effect and SYSLIB is a PDS, but not if SYSLIB is a PDSE. > > The error is IGYLI0053-U A library read error occurred during "BASIS" > processing. No member was found or there was a bad block. > > //S1 EXEC PGM=IGYCRCTL,PARM='COPYLOC(MYUNIX,PATH("valid.unix.path")' > //SYSLIB DD DSN=PDS(E) containing GCOPYA,DISP=SHR > //SYSIN DD * > BASIS GCOPYA > /* > // remaining COBOL compile JCL > > Above works if SYSLIB is a PDSE but fails if it is a PDS. Works either way > if you remove the COPYLOC. COPY seems to work okay; only BASIS seems to > fail. > > Just tried a COPYLOC with a DSN rather than a PATH and it still fails. > > Would be curious what others think or if anyone wanted to try to duplicate. > This is in Dallas so no ability to open a PMR. > > Charles > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN