In SG247419 page 94 Implementation Rexx support in SDSF it say PARM="" or null.
Respectfully, Willie C. Rouse Senior Mainframe Consultant Prince George's County, Maryland Office of Information Technology 9201 Basil Court/ Room B8 Largo, MD 20774 Voice: 301-883-7189 Fax: 301-883-3790 -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Leonardo Vaz Sent: Wednesday, February 27, 2013 12:50 PM To: [email protected] Subject: Re: SDSF Rexx Issue - to copy SYSOUT into PDS You are executing IEBGENER with parm "Parm DDlist", pretty much like in a JCL with the following card: // EXEC PGM=IEBGENER,PARM="Parm DDlist" And IEBGENER is giving you a RC=12, because that's not valid. Leonardo Vaz -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of saurabh khandelwal Sent: Wednesday, February 27, 2013 10:02 AM To: [email protected] Subject: SDSF Rexx Issue - to copy SYSOUT into PDS Hello, I am trying to run SDSF rexx to copy SYSOUT into PDS present in Implementing REXX Support in SDSF manual. I am able to create members( members name starting with Job id) in the PDS. But the data is not getting populated in these members from Job outputs. The issue which I issue is 328 *-* address LINKMVS "IEBGENER Parm DDlist" >L> "IEBGENER Parm DDlist" +++ RC(12) +++ I am not able to resolve this issue. I am using below inputs in Rexx and JCL to run this program. From the Job I am supplying only these three parameter. JOB(*) PDS(TEST12.SDSF.OUT) DDNAME(JESMSGLG) And in Rexx below are my inputs JobPattern = "JOB*" OwnerPattern = "TEST12" JobClass = "" Destination = "" CondCode = "" DdName = "" PdsDsn = "" Error = "NO" MemberRule = "JOBID" -- Thanks & Regards Saurabh ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN This E-mail and any of its attachments may contain Prince George’s County Government or Prince George's County 7th Judicial Circuit Court proprietary information or Protected Health Information, which is privileged and confidential. This E-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this E-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this E-mail is strictly prohibited by federal law and may expose you to civil and/or criminal penalties. If you have received this E-mail in error, please notify the sender immediately and permanently delete the original and any copy of this E-mail and any printout. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN