On Mon, 14 Dec 2020 12:55:27 -0600, Pierre Fichaud <[email protected]> wrote:

>I am trying to connect the the system logger but get the following:
>
>12.35.35 STC07110  IXG231I IXGCONN REQUEST=CONNECT TO LOG STREAM 
>XXXXXX.YYYYY.PRF1.MSGS  045   
>   045             DID NOT SUCCEED FOR JOB PRF1.  RETURN CODE: 00000008  
> REASON CODE:          
>   045             0000080C  DIAG1: 00000004  DIAG2: 4714041D  DIAG3: 0107001B 
>  DIAG4:         
>   045             00000000                                                    
>                 
>
>4714 means that there is no space left on the volume.
>How can I point the system logger to other VOLSERs?
>The allocations always go to the same VOLSER.
>
>And how can I tell the system that I have other VOLSERs available for TSO 
>allocations ?
>
>Thanks in advance, Pierre.
>
>----------------------------------------------------------------------
>For IBM-MAIN subscribe / signoff / archive access instructions,
>send email to [email protected] with the message: INFO IBM-MAIN

I don't specify a volume for my DASD only log streams, I specify a HLQ and a 
dataclass SMS does the rest, I have a pool of volumes for log streams 
it would be best to define an SMS pool of volumes for DASD only logstreams or 
use a volume pool already defined

Carmen 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to