On 3/19/2021 11:09 AM, Joseph Reichman wrote:
Hi
When doing overlapped I/O is there a way to tell if the I/O had completed on
the subsequent reads
I check to see if the first fullword has been populated by the BDW
The DECB that you issue CHECK against contains an actual embedded ECB at
offset +0. There is an implied WAIT inside CHECK, but you can certainly
inspect the POST bit yourself and/or WAIT on the ECB yourself using
whatever mechanisms you have available (such as placing its address into
a larger WAIT list). Once the WAIT has been satisfied, you still need to
issue CHECK, but it runs immediately without suspending...
--
Phoenix Software International
Edward E. Jaffe
831 Parkview Drive North
El Segundo, CA 90245
https://www.phoenixsoftware.com/
--------------------------------------------------------------------------------
This e-mail message, including any attachments, appended messages and the
information contained therein, is for the sole use of the intended
recipient(s). If you are not an intended recipient or have otherwise
received this email message in error, any use, dissemination, distribution,
review, storage or copying of this e-mail message and the information
contained therein is strictly prohibited. If you are not an intended
recipient, please contact the sender by reply e-mail and destroy all copies
of this email message and do not otherwise utilize or retain this email
message or any or all of the information contained therein. Although this
email message and any attachments or appended messages are believed to be
free of any virus or other defect that might affect any computer system into
which it is received and opened, it is the responsibility of the recipient
to ensure that it is virus free and no responsibility is accepted by the
sender for any loss or damage arising in any way from its opening or use.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN