Before I have a look at your files, a question:  What FTP client did you use to 
upload the data?  When I use the Windows 10 ftp client to upload data where one 
or more records exceed the defined dataset LRECL, the ftp client complains and 
aborts the upload (or maybe that is the ftp server at the z/OS end doing the 
abort, I am not sure which).

I am curious how you managed to ftp upload data with too-long records in the 
first place.

"Doctor!  Doctor!  It hurts when I do that!"
"Don’t do that!"

Peter

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Robert Prins
Sent: Monday, August 30, 2021 6:35 AM
To: [email protected]
Subject: UPDTE - CBTTAPE 093

I've been using this program for quite a few years, found a problem that's been 
corrected, but today I seem to have found another issue, and I hope someone can 
tell me if its a bug or something else.

I'm trying to load a file uploaded from Windows to a PDS
(RECFM=VB,LRECL=259) and this works without problems. However, the PC uploaded 
file contains records that are longer than 255 characters for some members. 
They seem to be loaded correctly, I can Edit/View/Browse them.
However, once SuperC hits these members, either as a consequence of a select 
'*" or as a select of T*W*99 SuperC hangs, not just when invoked online from 
3,.13, but also when run in batch.

The hang even occurs when I'm comparing a member against itself.

I'm clueless, so I've created

https://urldefense.com/v3/__https://prino.neocities.org/temp/pc.h-hx.xmit__;!!Ebr-cpPeAnfNniQ8HSAI-g_K5b7VKg!aXdUlJSK_nntCCzQUnShv2d-CbsTvyjloivn_rzOiX3l25Ztdn_LHhQJXJ0g2LxoT4FjWQ$
https://urldefense.com/v3/__https://prino.neocities.org/temp/v496.file093.xmit__;!!Ebr-cpPeAnfNniQ8HSAI-g_K5b7VKg!aXdUlJSK_nntCCzQUnShv2d-CbsTvyjloivn_rzOiX3l25Ztdn_LHhQJXJ0g2LxcH3qPkQ$
<https://urldefense.com/v3/__https://prino.neocities.org/temp/v496.file09.xmit__;!!Ebr-cpPeAnfNniQ8HSAI-g_K5b7VKg!aXdUlJSK_nntCCzQUnShv2d-CbsTvyjloivn_rzOiX3l25Ztdn_LHhQJXJ0g2LyEiW9uNQ$
 > 
https://urldefense.com/v3/__https://prino.neocities.org/temp/h-h.zall.xmit__;!!Ebr-cpPeAnfNniQ8HSAI-g_K5b7VKg!aXdUlJSK_nntCCzQUnShv2d-CbsTvyjloivn_rzOiX3l25Ztdn_LHhQJXJ0g2LxJvwAkVQ$
https://urldefense.com/v3/__https://prino.neocities.org/temp/h-h.cntl.xmit__;!!Ebr-cpPeAnfNniQ8HSAI-g_K5b7VKg!aXdUlJSK_nntCCzQUnShv2d-CbsTvyjloivn_rzOiX3l25Ztdn_LHhQJXJ0g2Lzh4u-8Ww$
 

1) The PDS containing four members that hang SuperC
2) The original version of UPDTE I'm using
3) The PC uploaded file containing the four members in 1)
4) The JCL to load the PDS with the PC uploaded data - need to change a 
"vol=ref"

All four files require less than one track.

If anyone would like to have a look, I'd be grateful.

Robert
--

This message and any attachments are intended only for the use of the addressee 
and may contain information that is privileged and confidential. If the reader 
of the message is not the intended recipient or an authorized representative of 
the intended recipient, you are hereby notified that any dissemination of this 
communication is strictly prohibited. If you have received this communication 
in error, please notify us immediately by e-mail and delete the message and any 
attachments from your system.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to