Because the translator generates: Call 'DFHEI1' ..... And you don't want them dynamic.
Tony Thigpen Erik Janssen wrote on 9/21/21 9:57 AM:
Hello All, In the COBOL documentation at https://www.ibm.com/docs/en/cobol-zos/6.2?topic=environment-choosing-dynam-nodynam-compiler-option it is said that for example CICS requires the NODYNAM compile option. My idea was that the sole purpose of DYNAM vs NODYNAM was to control dynamic vs static calls, where DYNAM will always lead to dynamic calls, but with NODYNAM only a CALL literal will lead to a static call, a CALL identifier will still lead to a dynamic call. So is it only possible under CICS to use CALL literal in this case (must all calls be static), or can you still use dynamic calling with a CALL identifier? And if the latter is the case, then why is there a requirement to use NODYNAM? Is there some other effect of DYNAM vs NODYNAM that I'm not seeing? Kind regards, Erik Janssen. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
