Because the translator generates:
 Call 'DFHEI1' .....
And you don't want them dynamic.

Tony Thigpen

Erik Janssen wrote on 9/21/21 9:57 AM:
Hello All,

In the COBOL documentation at 
https://www.ibm.com/docs/en/cobol-zos/6.2?topic=environment-choosing-dynam-nodynam-compiler-option
 it is said that for example CICS requires the NODYNAM compile option. My idea 
was that the sole purpose of DYNAM vs NODYNAM was to control dynamic vs static 
calls, where DYNAM will always lead to dynamic calls, but with NODYNAM only a 
CALL literal will lead to a static call, a CALL identifier will still lead to a 
dynamic call. So is it only possible under CICS to use CALL literal in this 
case (must all calls be static), or can you still use dynamic calling with a 
CALL identifier? And if the latter is the case, then why is there a requirement 
to use NODYNAM? Is there some other effect of DYNAM vs NODYNAM that I'm not 
seeing?

Kind regards,

Erik Janssen.

----------------------------------------------------------------------